Chevrolet Cobalt Service & Repair Manual: Temperature Valve Actuator, Replace

The key should be in the OFF position when connecting the electrical connectors to ensure proper calibration.
1. Remove fuse labeled HVAC CTRL (BATT).
2. Remove steering column filler panel.
3. Disconnect air temperature actuator electrical connector.
4. Remove air temperature actuator screws.
5. Remove air temperature actuator.
6. Reverse procedure to install. Torque temperature actuator screws to 19 inch lbs.
    Heater Core, Replace
    1. Apply park brake. 2. Shift transmission into neutral. 3. Remove console shift lever bezel by carefully li ...

    Thermostat, Replace
    1. Remove intake manifold cover. 2. Drain cooling system into suitable container. A drain plug is located at the bottom of water pump. ...

    See also:

    Chevrolet Cobalt Service & Repair Manual. Battery Cable, Replace
    Ground Cable Battery To Battery Tray Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing any electrical component. Disconnect the battery ground to prevent an electrical spar ...

    Chevrolet Cobalt Owners Manual